Digital Multimeter/PC520M

PC520M

CE
 
TRMS

PC520M
 
PDF Manual
 
PC Link Software Picture

Introduction
Dot AC True RMS
Dot 3-4/5 digits 5 000 count 
Dot 0.08% Basic Accuracy
Dot Selectable 5 sensitivity for Hz 
Dot 0.01 ohm resolution 
Dot 0.01m V AC/DC resolution
Dot K-type temperature
Dot Capacitance 0.01nF up to 9.999mF
Dot Auto power off (Enable or Disable)
Dot Fast response Cont. Buzzer
Dot Fast speed bargraph (60times/sec.)
Dot Tilt stand
Dot Set off Beeper
Dot Protective holster 
Dot Logging 43,000 data points in built-in memory
Dot Call and Scrolling logged data in the LCD
Dot MAX & MIN logged data can appear in the LCD
Dot Search of MAX & MIN logged data at turning point
Dot Selection of measurement interval from 0.05s, 1s, 20s, 40s, 1min, 2min, 4min or 8min (From 0.2s for C & ohm, 0.4s for Hz)
Dot Automatic Standby mode during data logging to extend battery life
Dot Automatic stop of data logging when batter-ies are low to guarantee accuracy of every logged datum
Dot Download logged data to PC
  
Standard Accessory
1. Holster (H-50) x 1
2. Test Leads (TL-82) x 1set
3. Alligator Clip (CL-13) x 1set
4. Thermocouple (K-250PC) x 1
 
Optional Accessory
1. Clamp Probe (CL33DC)
2. Clamp Probe (CL-22AD)
3. Clamp Probe (CL-20D)
4. K-type adapter (K-AD)
5. Carrying Case (C-CD)
6. RS-232C cable (KB-RS2)
7. Software (PC Link / PC Link Plus)
 
Measurement Range and Accuracy
DC voltage 0.01mV ~ 1000V
AC voltage, True-rms 0.01mV ~ 1000V
DC current 0.1μA ~ 10.00A
AC current 0.1μA ~ 10.00A
Resistance 0.01Ω ~ 50.00MΩ
Capacitance 0.01nF ~ 9999μF
Frequency 5.000Hz ~ 125kHz
Temperature -50єC ~ 1000єC
Diode test Range : 2.000V
Open voltage : approx. 3.5V
Continuity Buzzer sounds at between 20Ω-120Ω
 
Features

Basic Features

Digital display

5 000 counts
 
Sampling rate
Approx. 5 times/sec (numeral display)
Approx. 60 times/sec (bargraph)

Analog bargraph 52 segments max
Best DC accuracy 0.08%
AC sensor AC True RMS
Data Related Features
Data hold Yes
Range hold Yes
Test lead resistance calibration Yes
RS-232 interface Yes
Stand-alone logging Yes
Other Features
Beeper set off Yes
Low battery indication / timing Yes / Approx. below 7V
Automatic power off / timing Yes / 17 minutes
Disable automatic power off Yes
Auto / manual ranging Yes / Yes
Holster Yes
Tilt stand Yes
Separate battery / fuse access Yes
   
General Specifications
Accuracy temperature 18єC ~ 28єC 75% RH max.
No condensation
Operating temperature 0єC ~ 35єC 80% RH max.
No condensation
36є
C ~ 50єC 70% RH max.
No condensation
Storage temperature
Battery removed
-20єC ~ 60єC 80% RH max.
No condensation
Power supply Single alkaline 9V battery
NEDA1604
IEC6LF22 or 6LR61 x 1
Battery life 100hours
Environmental condition Operating altitude < 2000m
Pollution degree II
Fuse protection 0.63A / 250V -- 5.2 x 20mm IR 1.5kA
12.5A / 500V -- 6.3 x 32mm IR 20kA
Dimension including holster 179(H) x 87(W) x 55(D) mm
Weight including holster Approx. 460g
Transient (surge) protection 6.5kV (1.2/50μs surge)
CE mark Yes
Safety V/D/R/C/CAP/Hz
CAT III for 600V DC&AC
CAT II for 1kV DC & AC
μA/mA
CAT II 250V AC&150V DC
A
CAT II 500V AC&300V DC
E.M.C. EN55022 (1994/A1, 1995/Class B)
EN50082-1 (1992)
Warranty ( years ) 3
Calibration certificate with data Optional
 

на главную страницу